Wuxi Fenigal Science & Technology Co., Ltd.

Wuxi Fenigal Science & Technology Co., Ltd Manufacturer and Supplier for Industrial & Lighting Products

Manufacturer from China
Verified Supplier
6 Years
Home / Products / ATS Automatic Transfer Switch /

PC Class ATS Automatic Transfer Power Changeover Switch 4P Three Positions Socomec

Contact Now
Wuxi Fenigal Science & Technology Co., Ltd.
Visit Website
City:wuxi
Province/State:jiangsu
Country/Region:china
Contact Person:MrHarry
Contact Now

PC Class ATS Automatic Transfer Power Changeover Switch 4P Three Positions Socomec

Ask Latest Price
Video Channel
Brand Name :Fenigal/OEM
Model Number :ATS AC CB Class
Certification :CE,CCC
Place of Origin :China
MOQ :1 unit
Price :Negotiate
Payment Terms :T/T, Western Union
Supply Ability :10,000pcs/month
Delivery Time :5-8 working days bulk order negotiate
Packaging Details :Standard export carton
Product name :Dual Power Automatic Transfer Switch ATS
Max. voltage :690V
Control power supply voltage :400V, 380V, 220V, 480V
Pole :4P
Current :400A
Operation type :Manual
voltage :63A
Standard :IEC60947-6-1
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

PC class 4P Three Positions Socomec automatic transfer power Changeover Switch

PC-Class dual-power supply automatic switch(here in after ATSE) is the latest company Technology development of high-tech products. It is line with GB/T14048.1-2006,GB/T14047.11-2002 superscript. And also with “high-rise buildings fire norms” and “Architectural Design fire norms”, "Emergency Lighting Design Guide” “civil electrical design specifications”

Small in volume, convenient in installation

  • Self-input and self-restoring, Self-input without self-restoring, automatic or manual is all depends on you.
  • You can choose integral type or split type
  • 2 Pole,3 Pole,4 Pole all you can choose
  • Running parameter could be adjusted
  • Rated voltage of 400V,rated current is from 16Amp to 3200Amp

Automatic transfer switch Application:

  • Automatic transfer switch mainly used for distribution or electromotor network, which under voltage 220V/380V/400V, Rated current 16A-3200A.
  • Main power and standby power or mutual standby power change over system or city power and generator. Utility to Utility or Utility to Generator
  • Widely used at the field of important power supply site, which transport, high-rise building,

    industrial assembly line, television stations need electricity for the important parts. Main power Emergency Power can be power grids, with Self-excitation generator sets, battery, and so on.

    Structure and characteristic

Splited Modular Genset Manual ATSE is composed of switch body and controller. Adopt the electromaghetic driver, the working power of controller transfer is based on the main power and the standby power. AC 220V power supply, without additional source. Switch body have an electrical or mechanical switch instruction as an isolation indicator switch.

Model YES1-32C YES1-40C YES1-63C YES1-125C
Rated current(A) 25,32 40 63 125
Opearting current(A) 3.5
Rated short time current(KA) 5
Service Life Mechanical 8000
Electric 3000
Pole 2P 3P 4P 2P 3P 4P 2P 3P 4P 2P 3P 4P
Weight(KG) 3.2 3.7 4.2 4 4.5 5.5 4 4.5 5.5 4 4.5 5.5
Operating Cycle(s/time) 10

Normal running time and installation conditions

1.Ambient air temperature

Temperature should be within -5℃~40℃, and the average temperature within 24h should not exceed 35℃.

2.Altitude

Altitude of the installation site should not exceed 2000m.

3.Atmospheric conditions

The relative humidity of the installation site should not exceed 50% at maximum temperature 40℃, and it will be higher at minimum temperature -5℃, for instance, 90% at +20℃. Please take measures for the dew on product surface caused by temperature change.

4.Class of pollution

Pollution class of ATS meets the specified level of GB/T14048.11.

5.Installation category

Installation category of ATS meets the specified category in GB/T14048.11

Matterts need attention

1.Manual/automatic operation

ATS with automatic operation can ensure power generation and power-off performances, but for ATS with manual operation , it cannot ensure the above performance due to the speed of power generation and power-off or operator differences. Excessive silver alloy loss may occur during manual power generation and power down. Therefore, set the selector switch at the manual position under normal condition, and pull it to the manual position when all power is turned off to check and maintain the operating system and contacts. After the manual operation is completed pull the selector back to the automatic position.

2.Control circuit

ATS will be active in an instant. After the conversion is complete, the coils in the control circuit are disconnected by the internal converter. The coil can operate normally with a rated voltage of 80%~110%, and too low voltage may cause the coil to heat up or even ignite.

PC Class ATS Automatic Transfer Power Changeover Switch 4P Three Positions Socomec

PC Class ATS Automatic Transfer Power Changeover Switch 4P Three Positions Socomec

PC Class ATS Automatic Transfer Power Changeover Switch 4P Three Positions Socomec

Inquiry Cart 0